Pneumatic Diaphragm Valve-Plastic Actuator Type

Pneumatic Diaphragm Valve-Plastic Actuator Type

Features:

● High cycle life, excellent sealing performance.

● Light weight and excellent corrosion resistant, which due to unique thermoplastic construction.

● All optional Equipment can easily be added or removed in the field.

● Small flow resistance, high flow capacity, and the positioner can be installed to achieve flow control.

● The adjustable closing travel stop mechanism is designed to enhance the service life of the diaphragm and simplify the maintenance process.

● Patent No: ZL202111674037.9

Contact Us

Pneumatic Diaphragm Valve-Plastic Actuator Type Details

Optional Parameter List

Body Material

Diaphragm Material

Connection Type

Connection Standard

Action

Option

FRPP

PTFE

Flange Type

HG

Double Acting PN10

Limit Switch

PPH

PFA

True Union Type

DIN

Air to Close PN10

 Speed Controller

CPVC

F46

 

ANSI

Air to Open PN6

Solenoid valve

UPVC

EPDM

 

JIS

Air to Open PN10

Positioner

PVDF

FKM

     

Filter Regulator



Dimensions Table (mm)

DN

D(mm)

L(mm)

 d

L2

Socket end

Thread end

HG/DIN

JIS

ANSI

HG/DIN

JIS

ANSI

HG/DIN

JIS

ANSI

HG/DIN

JIS

ANSI

15

65

70

60

125

110

 110

20

22

21.3

Rcl/2

PT1/2

NPT1/2

155

20

75

75

70

135

120

 120

25

26

26.7

Rc3/4

PT3/4

NPT3/4

165

25

85

90

79

145/160

130

 130

32

32

33.4

Rcl

PT1

NPT1

173

32

100

100

89

160/180

160

 160

40

38

42.2

Rc1-1/4

PT1-1/4

NPT1-1/4

248

40

110

105

98

180

180

 180

50

48

48.3

Rc1-1/2

PT1-1/2

NPT1-1/2

257

50

125

120

121

210

210

 210

65

 60

60.3

Rc2

PT2

NPT2

292



Actuator parameter table

Actuator Specification (Double Acting)

Actuator Specification (Air to Open)

Actuator Specification (Air to Close)

DN mm

15

20

25

32

40

50

DN mm

15

20

25

32

40

50

DN mm

15

20

25

32

40

50

Operating Pressure Mpa

0.4-0.6

     Operating Pressure Mpa

0.4-0.6

    Operating Pressure Mpa

0.4-0.6

Air Consumption(0.4Mpa)

1.25

1.25

1.29

1.29

4.35

4.8

Air Consumption(0.5Mpa)

0.55

0.55

0.59

0.59

2.08

2.37

Air Consumption(0.4Mpa)

0.75

0.75

0.79

0.79

2.63

2.82

Air Supply Bore

RC1/4

  Air Supply Bore

RC1/4

  Air Supply Bore

RC1/4

When the air supply to the double acting actuator is interrupted, the valve remains in its original state for a certain period of time. When the air supply to the actuator is interrupted, the valve closes. When the air supply to the actuator is interrupted, the valve opens

CONTACT WITH US
12

years of
experience

About Us

Ningbo Baodi Plastic Valve Co., Ltd. is professional China Pneumatic Diaphragm Valve-Plastic Actuator Type Manufacturers and OEM/ ODM Pneumatic Diaphragm Valve-Plastic Actuator Type Factory .Founded in 2006, the enterprise has established ISO9001 quality system to support the quality guideline: supported by Technology, Meticulously Researching, Professionally Manufacturing and Permanently Creating New Records. The first class production equipments and advanced manufacturing skills are introduced at the same time, involving KRAUSS-MAFFEL CPVC pipe production line and Haitian CPVC Plastic Molding Machine of 2800 tons. In order to ensure the quality of Pneumatic Diaphragm Valve-Plastic Actuator Type , the raw materials like CPVC and PVDF are wholly imported from Noveon (USA) and Atofina (France).
25000

M2
Built-up area

Honor

  • honor
  • honor
  • honor
  • honor
  • honor
  • honor
  • honor
  • honor
  • honor
  • honor
  • honor
  • honor

NEWS CENTER

We aim to meet all our customers’ request by good quality and service. Welcome your inquiry and visits!

  • How to choose the installation position of the check valve

    Check valves play a vital role in fluid delivery systems. Their reasonable installation position directly affects the system's operating efficiency, safety, and convenience of later maintenance. Choosing an appropriate installation position can not only effectively prevent fluid backflow, leakage, a...

    05May
  • What factors affect the performance of the check valve

    The check valve is an indispensable control element in the industrial pipeline system, and its performance directly affects the safety, reliability and operating efficiency of the fluid conveying system. The performance of the check valve is affected by many factors, including material selection, st...

    28Apr
  • What factors should be considered in the design of the valve body structure of the manual ball valve

    The reliability and safety of the valve body under various working conditions. To this end, the selected materials must not only have good mechanical properties, but also meet the requirements of fluid characteristics and working environment. When selecting the valve body material of a manual ball v...

    21Apr
  • What factors should be considered in the design of manual ball valve sealing ring

    The design of sealing rings plays a vital role in industrial applications. Its material selection, shape and size, wear resistance, and fluid properties directly affect the quality of sealing performance. In terms of material selection for sealing rings, materials such as PTFE (polytetrafluoroethyle...

    14Apr
  • What are the installation steps of automatic butterfly valve

    During the installation of the automatic butterfly valve, the preliminary preparation work is crucial. First of all, it is necessary to carefully check the model and specifications of the selected automatic butterfly valve to ensure that it is perfectly matched with the pipeline system. In addition,...

    07Apr
  • What are the common faults when installing automatic butterfly valve

    During the installation of automatic butterfly valves, the sealing surface problem is one of the common faults, which directly affects the performance and reliability of the valve. Damage to the sealing surface or the presence of impurities is the main cause of leakage. Before the valve is installed...

    31Mar